Sterling 10 User Manual
Page: 10 RINS415-9
3. MASTER USER ONLY FUNCTIONS
The following operations can only be performed by the Master User. The panel distinguishes
who the user is by reading the last code that was entered to disarm the system. If the last
code entered was by a Limited User, then these functions won’t be available. Therefore to
access these functions enter your Master Code (the panel will start arming), then enter your
master code again (to disarm the panel), then these functions will be available.
3.1 Event Log Reset
LCD Keypad
Press the key
Then the key and scroll to ‘CLEAR LOG’.
Press the key to accept.
A two-tone sound will be heard stating the event log has now been cleared.
NOTE: This function will only be available if enabled by your engineer.
ICON keypad
Press the Ckey,
Followed by the key.
A two-tone sound will be heard stating the event log has now been cleared.
NOTE: This function will only be available if enabled by your engineer.
3.2 System Test
The System Test function checks the display of the keypad, the strobe, the bell and the internal
sounder if these are connected.
LCD Keypad
Press the key
Then the key and scroll to ‘SYSTEM TEST’.
Press the key to accept.
The Following will be displayed:
Ente
Sterling 10 User Manual
RINS415-9 Page: 11
Press the key to perform the next test: ‘STROBE TEST’ will then be displayed.
Press the key to perform the next test: ‘BELL TEST’ will then be displayed.
Press the key to perform the next test: ‘SOUNDERS TEST’ will then be displayed.
Press the key once more to exit System Test.
ICON Keypad
Press the Ckey, followed by the key.
Press the C key to perform the Display Test – all symbols are displayed except for the Fault
symbol.
Press the Ckey to perform the Strobe Test.
Press the C key to perform the Bell Test.
Press the C key to perform the Internal Sounders Test.
Press the C key to exit the System Test.
3.3 Walk Test Mode
The Walk test function allows each of the Arm Modes to be checked in order to verify that all the
intruder detectors on the alarm system are functioning correctly. When undergoing a walk test the
Engineer or Master User can choose which of the Arm Modes they wish to test. Any zone used in
that Arm Mode will cause a chime at the keypad or extension speaker if they are triggered.
LCD Keypad
Press the key
Then the key and scroll to ‘WALK TEST’.
Press the key to accept.
Use the key to choose the desired Arm Mode you wish to Walk Test,
Then press the key.
Enter the 4-digit Master Code.
After the countdown timer (default 30 seconds) has stopped, the system is armed and ready to be
tested. When the walk test mode is enabled the keypad will display any activated zones. As shown
below:
This enables all the zone configurations to be walk tested individually.
To exit the walk test enter your 4-digit user code.